Veris Verabar V150 Spec Sheet Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Veris Verabar V150 Spec Sheet. Veris Verabar V150 Spec Sheet User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Regular Models
V150 Spring Lock
Threaded Components
Differential Pressure Flow Sensors
Verabar
®
Model
V150
Temperature
Pressure
Limits
(ANSI Class)*
600#
1440 psig @ 100°F
(99.3 Bars @ 38°C)
825 psig @ 800°F
(56.9 Bars @ 426°C)
V150 Spring Lock
Pipe Connection Threaded (NPT)
Mounting Type Spring loaded sensor with packing gland
• Best valued model
• Blow-out and leak proof design
Features and
• Preloads sensor to opposite wall
Benefits
• Four times stronger than conventional mountings
• Eliminates need for opposite end support
• Compensates for changes in pipe diameter
due to pressure, temperature or mechanical force
• Air (compressed, combustion)
• Natural gas
Applications • Water (raw, cooling, feedwater)
• High velocity fluids
• Steam
Special Designs
• Custom mounting, lengths, materials,
Consult Factory
instrument connections, etc.
• Short straight run
Model Specifications V150
Sensor Code 05 10 15
Sensor Diameter 7/16” (11mm) 7/8” (22mm) 1-3/8” (35mm)
Accuracy ±1% of flow rate; ±0.5% if calibrated
ANSI Class* 600# 600# 600#
Pipe Size
2”- 6” 6”- 42” 12”- 60”
(50mm-150mm) (150mm -1050mm) (300mm-1500mm)
Instrument Connection 1/2” NPT 1/2” NPT or Direct Mount
Components Furnished Weld coupling, Spring lock mounting assembly
Weld Coupling Size 3/4” NPT 1” NPT 2” NPT
The Most Accurate and Reliable Technology
for Measuring Gas, Liquid and Steam…
Developed from aerospace technology, the Verabar®
averaging pitot flow sensor provides unsurpassed
accuracy and reliability. With its solid, one-piece
construction and bullet shape, the Verabar
makes flow measurement leak proof
and precise.
The unique sensor shape
reduces drag and flow
induced vibration.
The location of the
low-pressure ports
eliminates the potential
for clogging and improves
signal stability.
* DIN and JIS flanges available. Consult factory.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Regular Models

Regular ModelsV150 Spring LockThreaded ComponentsDifferential Pressure Flow SensorsVerabar®Model V150TemperaturePressure Limits(ANSI Class)*600#1440

Page 2

Verabar®VerabarFlow Calculation ProgramFlow Calculation Program5.Flow CalculationAll Verabar applications require a flow calculation to verify the DP,

Page 3 - Ordering Information

Code OptionsWNSFor stainless steel pipes.For V150, furnished with one SS weld coupling.V150 8”sch40 10 H R C2NC Typical Model NumberOrdering Informati

Page 4

6315 Monarch Park Place •Niwot, CO 80503 USA •Phone: 303-652-8550 •Fax: 303-652-8552E-Mail: [email protected] •Website: www.veris-inc.comTrue

Commentaires sur ces manuels

Pas de commentaire