Hot Tap Models
V450 Low Pressure Hand Insertion
Flanged Components
Differential Pressure Flow Sensors
Verabar
®
The Most Accurate and Reliable Technology
for Measuring Gas, Liquid and Steam…
Developed from aerospace technology, the Verabar®
averaging pitot flow sensor provides unsurpassed
accuracy and reliability. With its solid, one-piece
construction and bullet shape, the Verabar
makes flow measurement leak proof
and precise.
The unique sensor shape
reduces drag and flow
induced vibration.
The location of the
low-pressure ports
eliminates the potential
for clogging and improves
signal stability.
Model
V450
V450 Hot Tap
Pipe Connection Flanged
Mounting Type Flanged ball or gate access valves
• Lowest cost flanged hot tap model
• Installation, insertion & retraction without system shutdown
Features and Benefits • Hand insertion and retraction for low pressures (no threaded rods)
• Retaining ring loads sensor to the opposite wall
• Can mount to existing flanges or valves
• Low pressure
• Air
Applications • Stack/flue gas
• Water
• Hydrocarbon and other gases
Special Designs • Custom mounting, lengths, materials, instrument connections, etc.
Consult Factory • Short straight run
Model Specifications V450
Sensor Code 10 15
Sensor Diameter 7/8” (22mm) 1-3/8” (35mm)
Accuracy ±1% of flow rate; ±0.5% if calibrated
Max Pressure 30 psig (2.1 Bars) 10 psig (0.7 Bars)
Pipe Size
6”- 42” 12”- 60”
(150mm -1050mm) (300mm-1500mm)
Instrument Connection 1/2” NPT or Direct Mount
Components Furnished Weld coupling, weldneck flange, access valve, gaskets, studs & nuts
Flange Size 1-1/2” 2”
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Hot Tap Models

Hot Tap ModelsV450 Low Pressure Hand InsertionFlanged ComponentsDifferential Pressure Flow SensorsVerabar®The Most Accurate and Reliable Technology f

Page 2

Verabar®VerabarFlow Calculation ProgramFlow Calculation Program5.Flow CalculationAll Verabar applications require a flow calculation to verify the DP,

Page 3 - Ordering Information

Model Hot Tap • Low Pressure Hand InsertionV450 Hand Insert/Retract, Low PressurePipe Size and Schedule or Exact ID and Wall ThicknessCode Sensor

Page 4

6315 Monarch Park Place •Niwot, CO 80503 USA •Phone: 303-652-8550 •Fax: 303-652-8552E-Mail: [email protected] •Website: www.veris-inc.comTrue

Commentaires sur ces manuels

Pas de commentaire